Isivinini esiphansi se-centrifuge esiqandisiweiyi-centrifuge enezinjongo eziningi enesivinini esikhulu esiqandisini, enobuchwepheshe obuphambili be-centrifuge ehlakaniphile.Isetshenziswa kabanzi kwezokwelapha, i-biochemistry, ubunjiniyela bezakhi zofuzo, i-immunology kanye neminye imikhakha.Kuyithuluzi elisetshenziselwa ukuhlukaniswa kwe-centrifugal ezibhedlela, amayunithi ocwaningo lwesayensi namanyuvesi kuwo wonke amazinga.
I-centrifuge enesivinini esiphansi esiqandisiniizinyathelo zokwandisa impilo:
1. Ngemva kokubeka i-centrifugation, yomisa amanzi ekamelweni eliyi-centrifugal, bese usebenzisa igrisi yokuthambisa engathathi hlangothi kukhoni yesipindle se-motor masonto onke ukuze uvimbele ukugqwala kwe-shaft ejikelezayo.Uma ungadingi umthamo omkhulu we-centrifuge esiqandisini isikhathi eside, i-rotor kufanele isuswe, isulwe futhi ibekwe endaweni eyomile ukuvimbela ukugqwala.
2, ipulaki yamandla eyinhloko kufanele isuswe lapho ithuluzi lingasetshenziswa isikhathi eside noma ukulungiswa.Uma kungenjalo, ithuluzi lizokhokhiswa, ikakhulukazi uma ukulungiswa kuthambekele ezingozini zokuphepha.
3, ukuze kuvikelwe i-compressor yesiqandisi, isikhathi phakathi kwensimbi namandla sikhulu kunemizuzu emi-3, ngaphandle kwalokho i-compressor izolimala.
4. Uma i-rotor ingasetshenziswa, kufanele isuswe ekamelweni le-centrifugal, ihlanzwe futhi yomiswe nge-detergent engathathi hlangothi ngesikhathi ukuvimbela ukugqwala kwamakhemikhali, futhi igcinwe endaweni eyomile neyomoya.Akuvunyelwe ukukhuhla i-rotor nge-detergent engathathi hlangothi, futhi akuvunyelwe ukomisa i-rotor ngomoya oshisayo.Umgodi ophakathi we-rotor kufanele uvikelwe ngamafutha amancane.
5, ukuze kuqinisekiswe umphumela wokuqandisa, lapho izinga lokushisa elizungezile lingaphezu kuka-30 ° C, i-rotor kanye negumbi le-centrifugal kufanele lipholiswe ngaphambili, i-rotor kufanele futhi inciphise isivinini sokusebenza kuka-15%.
6, ithubhu ye-centrifugalkufanele ibuyekezwe njalo, kwenqatshelwe ngokuphelele ukusebenzisa ithubhu ye-centrifugal eduze nokugqashuka.
I-7, ngaphambi kokusetshenziswa ngakunye kufanele unake ukuhlola i-rotor yamaphuzu okugqwala nokuqhekeka okuhle, ukuvimbela ukusetshenziswa kwama-rotor agqwalile noma aqhekekile, ukusetshenziswa okungaphezu kokuphila kweshalofu ye-rotor, ukuqinisekisa ukuphepha komuntu siqu.
I-8, ukusetshenziswa kwe-rotor ye-centrifuge enkulu efrijini kufanele kuqinisekiswe ukusetha inombolo ye-rotor ilungile.Uma inombolo ye-rotor isethwe ngokungalungile.Kuzokwenza ukuthi i-rotor ijubane noma ingafinyeleli umphumela oyifunayo we-centrifugal.Ikakhulukazi, ukusetshenziswa kwejubane elidlulele kungaholela engozini ebulalayo yokuqhuma kwe-rotor, okungafanele kube budedengu.
sicela uthinte iWhatsapp & Wechat: +86 180 8048 1709